A feed-though condition may cause false readings during circuit testing and can happen when a load is still connected to the circuit being tested.

A) True
B) False

Correct Answer

verifed

verified

When testing a 'live' 50 amp, 125/250 volt range receptacle using a voltage tester, you should get a 240 volt reading when measuring from the grounded conductor connection (W slot) to either ungrounded conductor connection (X or Y slot).

A) True
B) False

Correct Answer

verifed

verified

In the NEC, Article __________ contains requirements for grounding and bonding residential electrical systems.


A) 200
B) 230
C) 240
D) 250

E) B) and C)
F) None of the above

Correct Answer

verifed

verified

GFCI protection is not required for 125 volt, 15- or 20 amp receptacles located __________.


A) in bathrooms
B) in finished basements
C) in garages
D) outdoors

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

The NEC requires a minimum of __________ 20 amp bathroom branch circuit in a dwelling unit.


A) 1
B) 2
C) 3
D) 4

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

When holes are bored through wood framing members, they must be at least __________ inches from the nearest edge of the wood member.


A) 1
B) 1-1/8
C) 1-1/4
D) 1-1/2

E) None of the above
F) B) and C)

Correct Answer

verifed

verified

When testing a 'live' 120 volt receptacle using a voltage tester, you should get a 120 volt reading when measuring from the grounded conductor connection (long slot) to the grounding conductor connection (U-shaped slot).

A) True
B) False

Correct Answer

verifed

verified

Explain 'feed through' as it applies to using a continuity tester when testing a lighting circuit.

Correct Answer

verifed

verified

All lamps must be removed. Oth...

View Answer

An electrician is testing a 15-amp, 125-volt rated duplex receptacle with a voltage tester. The tester indicates 120 volts between the ungrounded slot and the grounded slot. The tester also indicates 120 volts between the grounded slot and the grounding slot. The likely cause is __________.


A) an open equipment grounding path
B) a short circuit in the cable feeding the receptacle
C) an open grounded circuit conductor
D) reversed polarity at the receptacle

E) All of the above
F) A) and B)

Correct Answer

verifed

verified

In a sub-panel, a green bonding screw provided by the panel manufacturer must be installed to electrically bond the grounded feeder conductor and the equipment grounding conductors to the panel enclosure.

A) True
B) False

Correct Answer

verifed

verified

In resdidential applications, Type NM cable is permitted to pass through environmental air handling spaces perpendicular to the long dimension of the space.

A) True
B) False

Correct Answer

verifed

verified

Recessed lighting fixtures installed in insulated ceilings so that the insulation is covering the fixture must be labeled ____________________.

Correct Answer

verifed

verified

A(n) __________ is an unintended low-resistance path through which current flows around, rather than along, a circuit's intended current path.


A) grounded circuit
B) open circuit
C) short circuit
D) grounding circuit

E) None of the above
F) B) and D)

Correct Answer

verifed

verified

The minimum size of service for a single-family dwelling unit permitted by the NEC is __________ amperes.


A) 60
B) 75
C) 100
D) 150

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

According to the NEC, lighting fixtures must be installed in clothes closets.

A) True
B) False

Correct Answer

verifed

verified

Describe what a circuit tracer does and when it is used.

Correct Answer

verifed

verified

A circuit tracer is used to determine wh...

View Answer

All branch circuits supplying 125-volt, 15- and 20-ampere outlets in residential family rooms, living rooms, dining rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, or similar rooms must be protected by a(n) __________.


A) fuse
B) circuit breaker
C) GFCI device
D) AFCI device

E) A) and D)
F) None of the above

Correct Answer

verifed

verified

An electrician is testing a 20-amp, 125-volt duplex receptacle with a voltage tester. The tester indicates 120 volts between the ungrounded slot and the grounded slot. The tester also indicates 0 volts between the ungrounded slot and the grounding slot. The likely cause is __________.


A) an open equipment grounding path
B) reversed polarity at the receptacle
C) an open grounded circuit conductor
D) a short circuit in the cable feeding the receptacle.

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

At kitchen countertops, receptacle outlets must be installed so that no point along the wall line is more than __________ feet, measured horizontally, from a receptacle outlet in that space.


A) 2
B) 6
C) 10
D) 12

E) B) and D)
F) A) and B)

Correct Answer

verifed

verified

An electrician tests a 30 amp, 250 volt dryer receptacle with a voltage tester. The tester indicates 120 volts between the X and Y slots. The tester also indicates 240 volts between the X and W slots. The tester also indicates 0 volts between the Y and the grounding slot. The likely cause is __________.


A) an open grounding path
B) the wires are reversed between the W and the Y slots
C) the wires are reversed between the X and the Y slots
D) an open grounded conductor

E) B) and C)
F) None of the above

Correct Answer

verifed

verified